FSL SPECIFICATIONS

Dimensional
Height
50” (127 cm)
Width
22” (56 cm)
Depth
28” (71 cm)
Weight
222 lbs (101 kg)
Connections
Inlet with 3-way valve
FSL05-FSL10: 1” FNPT FSL20-FSL30: 1.5” FNPT
Outlet
FSL05-FSL10: 1” FNPT FSL20-FSL30: 1.25” FNPT
Operating Temperature
Fluid Temperature
30°F to 225°F (0°C to 105°C)
Ambient Temperature
-4°F to 104°F (-20C to 40C)
Materials of Construction
Vessel
Carbon steel with industrial coating
Electric Motor
TEFC, 56-215 frame
0.5-3 hp, 1450-1750 RPM, see Appendix for amp ratings.
Motor Starter
MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection.
Pump
Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures.
Pump Bypass
Full bypass at 150 psi (10 bar)2
Pneumatic Option Air Consumption
~40 cfm @ 80 psi3
Operating Temperature
M
Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000
A
Microglass high performance media combined with water removal scrim. βx[C] ≥ 4000
W
Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2)
Viscosity
2-5000 cSt4
Fluid Compatibility
Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options.
Hazardous Environment Options
Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord or cord reel will be included.

1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. Dimensions are approximations taken from base model and will vary according to options chosen.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 800 cSt for sizing requirements.

Lube Storage and Dispensing Systems

Order and customize your order quickly and easily.
vacuum dehydrator

V1P model shown,V1S model shown

Vacuum Dehydration Oil Purification System

A vacuum dehydrator is an industrial device that removes moisture and contaminants from lubricating oils and hydraulic fluids. It does so by utilizing vacuum pressure to lower the boiling point of water, allowing for efficient separation and extraction of impurities. For a vacuum dehydration oil purification system you can trust, turn to Bennett Filtration.

The V1 is our compact and mobile dehydration and high efficiency filtration solution. It prevents acidity and loss of lubrication properties caused by inefficient dehydration and high ingression. This vacuum oil dehydrator is ideal for rapidly removing all forms of water, including free, emulsified, and dissolved water and gas from hydraulic and lube oils.  


Explore this product’s FSL specifications below. If you would like more information or a quote, contact us today. You can reach us by phone, email, or online form—we look forward to hearing from you and improving your hydraulic operations with top-quality equipment.

FSL SPECIFICATIONS

Model
V1P
V1S
Height 1
50” (127 cm)
50” (127 cm)
Width 1
28” (71 cm)
34” (86 cm)
Depth 1
28” (71 cm)
24” (61 cm)
Weight 1
400 lbs (181 kg)
400 lbs (181 kg)
Inlet
¾” male JIC
¾” male JIC
Outlet
½” male JIC
½” male JIC
Operating Temperature
Fluid Temperature
32°F to 180°F (0°C to 82°C)
Ambient Temperature
-4°F to 104°F (-20C to 40C)
Materials of Construction
Frame
Carbon steel or stainless steel
Filter assembly
Aluminum and carbon steel
Electric Motor
TEFC with overload protection
Electric Connection
50’ (15 m) power cord supplied with machine.
Pump
Cast iron, positive displacement gear pump with internal relief.
Vacuum Pump
Dry Rotary Vane
Media Description
M
Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000
W
Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2)
Fluid Compatibility
Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester or skydrol fluid compatibility select fluid compatibility from special options.

1. Dimensions are approximations taken from base model and will vary according to options chosen.

Lube Storage and Dispensing Systems

Order and customize your order quickly and easily.
cart

Hydraulic Filter Cart

An industrial filter cart is a mobile filtration system designed to purify and transfer fluids in industrial settings. Depending on the viscosity of the fluids you need to purify, your cart needs will change. For lower-viscosity fluids, a low-viscosity filter cart is best. Bennett Filtration provides this equipment.

Our hydraulic filter cart is a fully self-contained mobile solution for bulk oil handling, fluid transfer, and reservoir or gearbox conditioning. It is ideal for lower-viscosity hydraulic oil, lube oil, and diesel fuel.

Take a look at the cart’s FSL specifications below to gauge if it’s a good fit for your operations. Then, if you would like more information or a quote, contact us today. You can reach us by phone, email, or online form. We look forward to helping you staff your hydraulic operations with the best equipment.

FSL SPECIFICATIONS

Dimensional
Height
45” (114 cm)
Width
20” (50 cm)
Depth
23” (58 cm)
Weight
125 lbs (57 kg)
Connections
Inlet
FC05-FC5: 1” male JIC (37° flare) FC10: 1.25” male JIC (37° flare)
Outlet
FC05-FC10 1” male JIC (37° flare) FC20: 1.25” male JIC (37° flare)
Hoses
FC05-FC5: 1” x 10 ft (2.4 m) FC10:1.25” x 10 ft (2.4 m) suction
1” x 10 ft (2.4 m) discharge
Operating Temperature
Fluid Temperature
30°F to 225°F (0°C to 105°C)
Ambient Temperature
-4°F to 104°F (-20C to 40C)
ΔP Indicator Trigger
22 psi (1.5 bar). Consult factory for other options.
Filter Assembly Bypass
25 psid (1.7 bard). Consult factory for other options.
Materials of Construction
Frame
Industrial coated steel
Filter Assembly
Aluminum head & canister
Hoses
Reinforced synthetic
Wands
Stainless Steel
Electric Motor
TEFC, 56-215 frame

0.5-3 hp, 1450-1750 RPM
Electric Connection
Voltages 230 V ac and under, single phase: 35’ (11 m) retractable cord reel included. NEMA 5-15 plug installed on Power Option 12. Voltages over 230 V ac: 35’ (11 m) power cord included.
Motor Starter
MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection.
Pump
Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures.
Pump Bypass
Full bypass at 150 psi (10 bar)2
Pneumatic Option Air Consumption
~40 cfm @ 80 p~40 cfm @ 80 psi3

35’ (11 m) retractable air hose included when pneumatic option selected (replaces electric cord reel).si3
Operating Temperature
M
Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000
A
Microglass high performance media combined with water removal scrim. βx[C] ≥ 4000
W
Stainless steel wire mesh media βx[C] ≥ 2
Viscosity
2-5000 cSt4
Fluid Compatibility
Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options.
Hazardous Environment Options
Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord will be included.

1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. 10 GPM pump is rated for intermittent duty only at pressures above 100 psi. Continual operation with dual clogged filters resulting in operating pressures over 100 psi will reduce pump life and/or cause premature pump failure.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 200 cSt for sizing requirements.

Lube Storage and Dispensing Systems

Order and customize your order quickly and easily.
Lube Storage and Dispensing Systems

Lube Storage and Dispensing Systems

Remove water and particulate to extend fuel injector life and increase combustion engine fuel efficiency. Ideal for large mining and construction fueling depots, diesel fueled turbines, backup generators, and smaller day tank dispensing or on-board fueling truck applications. With options for adding nonpowered units to existing fuel dispensing lines, there’s a perfect COD for all of your diesel applications.

FSL SPECIFICATIONS

1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. Female pipe port.
3. L38-CSV element combines coalesce and separator element functions into a single element. TEFLON® is a registered trademark of DuPont.

Lube Storage and Dispensing Systems

Order and customize your order quickly and easily.
Lube Storage and Dispensing Systems

Lube Storage and Dispensing Systems

A dedicated contamination solution for bulk oil handling, fluid transfer and reservoir or gearbox conditioning.

Enhance cleanliness by adding the FPL to an existing hydraulic system and extend the life of in-line filters.

FSL SPECIFICATIONS

Dimensional
Height
22” (58 cm)
Lenght
42” (107 cm)
Depth
12” (31 cm)
Weight
138 lbs (63 kg)
Connections
Inlet with 3-way valve
1” FNPT
Outlet
1” FNPT
Operating Temperature
Fluid Temperature
30°F to 225°F (0°C to 105°C)
Ambient Temperature
-4°F to 104°F (-20C to 40C)
ΔP Indicator Trigger
Standard MF110 Assemblies
18 psi (1.2 bar)
Special Options D1 + S1 (S75/D)
22 psi (1.5 bar)
Special Option D2 (DFN)
32 psid (2.2 bard)
Special Option P1 (PFH)
73 psid (5 bard)
ΔP Indicator Trigger
Standard MF110 Assemblies
25 psid (1.7 bard)
Special Options D1 + S1 (S75/D)
25 psid (1.7 bard)
Special Option D2 (DFN)
50 psid (3.4 bard)
Special Option P1 (PFH)
102 psid (7 bard)
Materials of Construction
Frame
Carbon steel with industrial coating
Electric Motor
TEFC, 56-145 frame
0.5-1 hp, 1450-1750 RPM
Motor Starter
MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection.
Pump
Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures.
Pump Bypass
Full bypass at 150 psi (10 bar)2
Pneumatic Option Air Consumption
~40 cfm @ 80 psi3
Media Description
M
Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000 (βx ≥ 200)
A
Microglass high performance media combined with water removal scrim. βx[C] ≥ 4000 (βx ≥ 200)
W
Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2)
Viscosity
2-5000 cSt4
Fluid Compatibility
Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or
Hazardous Environment Options
Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord will be included.

1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. 10 GPM pump is rated for intermittent duty only at pressures above 100 psi. Continual operation with dual clogged filters resulting in operating pressures over 100 psi will reduce pump life and/or cause premature pump failure.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 800 cSt for sizing requirements.

Lube Storage and Dispensing Systems

Order and customize your order quickly and easily.
Lube Storage and Dispensing Systems

High-Viscosity Filter Cart

An industrial filter cart is a portable system designed to filter and transfer fluids, ensuring that contaminants are removed from lubricants and hydraulic fluids during maintenance or service operations. This piece of equipment is essential for streamlining a variety of industrial operations. However, quality matters when it comes to the type of cart you invest in.

If you’re in need of a high-viscosity filter cart, Bennett Filtration has the perfect solution for your operations. Our product is a self-contained solution for high viscosity bulk oil handling, fluid transfer, and reservoir or gearbox conditioning. This heavy-duty filter cart is ideal for higher viscosity lube oil and highly contaminated fuel and hydraulic oil.

If you would like more information or a quote, contact us today by phone, email, or online form. We look forward to hearing from you and making your hydraulic operations as efficient as possible.

FSL SPECIFICATIONS

Dimensional
Height
57” (144 cm)
Width
30” (77 cm)
Depth
30” (77 cm)
Weight
351 lbs (159 kg)
Connections
Inlet with 3-way valve
FCL05-FCL5: 1” male JIC (37° flare) FCL10: 1.25” male JIC (37° flare)
Outlet
FCL05-FCL10: 1” male JIC (37° flare) FCL20-FCL30: 1.25” male JIC (37° flare)
Hoses
FCL05-FCL5: 1” x 10 ft (2.4 m) FCL10: 1.25” x 10 ft (2.4 m) suction1” x 10 ft (2.4 m) discharge
Operating Temperature
Fluid Temperature
30°F to 225°F (0°C to 105°C)
Ambient Temperature
-4°F to 104°F (-20C to 40C)
Materials of Construction
Housing
Carbon steel with industrial coating
Hoses
Reinforced synthetic
Wands
Stainless steel
Electric Motor
TEFC, 56-215 frame
0.5-3 hp, 1450-1750 RPM, see Appendix for amp ratings.
Electric Connection
Voltages 230 V ac and under, single phase: 35’ (11 m) retractable cord reel included. NEMA 5-15 plug installed on Power Option 12. Voltages over 230 V ac: 35’ (11 m) loose cord included.
Motor Starter
MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection.
Pump
Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures.
Pump Bypass
Full bypass at 150 psi (10 bar)2
Pneumatic Option Air Consumption
~40 cfm @ 80 psi3 35’ (11 m) retractable air hose included when pneumatic option selected. Replaces 35’ (11m) electric cord reel.
Media Description
M
Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] = 1000 (βx = 200)
A
Microglass high performance media combined with water removal scrim. βx[C] = 1000 (βx = 200)
W
Stainless steel wire mesh media βx[C] = 2 (βx = 2)
VTM
β0.9[C] = 1000 particulate, insoluble oxidation by-product and water removal media
Viscosity
2-5000 cSt4
Fluid Compatibility
Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options.
Hazardous Environment Options
Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord or cord reel will be included.

1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. 10 GPM pump is rated for intermittent duty only at pressures above 100 psi. Continual operation with dual clogged filters resulting in operating pressures over 100 psi will reduce pump life and/or cause premature pump failure.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 800 cSt for sizing requirements.

Lube Storage and Dispensing Systems

Order and customize your order quickly and easily.
Lube Storage and Dispensing Systems

CFUM9 Model shown (2x MF90 in series)

Compact Filter Unit

A filter unit in a hydraulic system is what removes contaminants and impurities from the hydraulic fluid, ensuring clean circulation that protects system components and maintains optimal efficiency. The unit consists of a filter element inside housing that allows fluid to flow through. Additional components may include a bypass valve to prevent pressure buildup and access ports for monitoring and maintenance purposes. Though it may seem that a large piece of equipment is necessary to house all these components, that’s not necessarily true.  

Bigger isn’t always better. The Compact Filter Unit from Bennett Filtration provides you with the best filtration at a size you can take anywhere. Tried and true, the CFU is the ultimate filtration system in power and mobility. And with easy-to-change cartridge-style MF90s, you can rest easy knowing your filtration will always exceed your expectations.

If you would like more information or a quote for an industrial filtration unit that won’t take up too much space, contact us today. You can reach us by phone, email, or online form. We look forward to helping you see what a Compact Filter Unit can do for your operations.

FSL SPECIFICATIONS

Dimensional
Height
21” (54 cm)
Lenght
21” (54 cm)
Width
12” (31 cm)
Weight
47 lbs (21 kg)
Connections
Inlet
¾” male JIC with 37° flare
Outlet
½” male JIC with 37° flare
Hoses
¾” x 8 ft (2.4 m) suction female JIC or BSPP swivel ½” x 8 ft (2.4 m) discharge female JIC or BSPP swivel
Operating Temperature
Fluid Temperature
30°F to 225°F ½” x 8 ft (2.4 m) discharge female JIC or BSPP swivel
Ambient Temperature
4°F to 104°F ½” x 8 ft (2.4 m) discharge female JIC or BSPP swivel
ΔP Indicator Trigger
22 psi (1.5 bar). Consult factory for other options.
Filter Assembly Bypass
25 psid (1.7 bard). Consult factory for other options.
Materials of Construction
Frame
Powder coated aluminum
Filter Assembly
Aluminum head
Hoses
Reinforced synthetic
Wands
Stainless steel
Element Bypass Valve
Nylon
Electric Motor
TEFC, 56C frame 7/16 hp, 1450-1750 RPM
Electric Connection
15’ (4.6 m) cord included installed on machine.
Pump
Positive displacement gear pump with relief valve. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures.
Pump Bypass
Full bypass at 150 psi (10 bar)2
Pneumatic Option Air Consumption
~15 cfm @ 60 psi3
Media Description
M
High performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000 (βx ≥ 200)
A
High performance media combined with water removal scrim. βx[C]  4000 (βx ≥ 200)
W
Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2)
Viscosity
Max viscosity rated for 200 cSt.4
Fluid Compatibility
Petroleum and mineral based fluids (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options.
Hazardous Environment Options
Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D.Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord will be included.

1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. Selecting pneumatic power option removes electric cord.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 200 cSt for sizing requirement.

Lube Storage and Dispensing Systems

Order and customize your order quickly and easily.
Lube Storage and Dispensing Systems

These specially designed systems are made to store, handle, and distribute lubricants, improve equipment functionality, and ensure proper maintenance.

New oil isn’t necessarily clean oil. That makes it essential to run a particle count on incoming deliveries and store lubricants in a filtered, moisture-controlled setting. Our fully scalable lube storage and dispensing system streamlines lubricant management to ensure they reach the right gearbox, hydraulic system or turbine base.

Our lube oil and hydraulic oil storage system pumps and filters your fluids from drums, circulates stored fluids until ISO particle counts are optimal, and disperses them through DFE rated filter elements. Recessed LED lighting, color-coding for brand and product specifications, and customizable storage capacities make this system easy to use in any workspace or facility.

We help you choose the right filtration equipment to meet your cleaning standards.

Contact us

keep browsing