FC Filter Cart
FSL High Viscosity Filtration Systems
A dedicated contamination solution for bulk oil handling and fluid transfer. Designed to excel in filtering particulate from heavily contaminated oil, the FSL keeps gearbox lubricant clean and equipment running efficiently.
Ideal for high viscosity gearbox or lube applications and highly contaminated fuel applications.
FSL SPECIFICATIONS
Dimensional | Height 50” (127 cm) | Width 22” (56 cm) | Depth 28” (71 cm) | Weight 222 lbs (101 kg) |
Connections | Inlet with 3-way valve FSL05-FSL10: 1” FNPT FSL20-FSL30: 1.5” FNPT | Outlet FSL05-FSL10: 1” FNPT FSL20-FSL30: 1.25” FNPT | ||
Operating Temperature | Fluid Temperature 30°F to 225°F (0°C to 105°C) | Ambient Temperature -4°F to 104°F (-20C to 40C) | ||
Materials of Construction | Vessel Carbon steel with industrial coating | |||
Electric Motor | TEFC, 56-215 frame 0.5-3 hp, 1450-1750 RPM, see Appendix for amp ratings. | |||
Motor Starter | MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection. | |||
Pump | Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures. | |||
Pump Bypass | Full bypass at 150 psi (10 bar)2 | |||
Pneumatic Option Air Consumption | ~40 cfm @ 80 psi3 | |||
Operating Temperature | M Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000 | A Microglass high performance media combined with water removal scrim. βx[C] ≥ 4000 | W Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2) | |
Viscosity | 2-5000 cSt4 | |||
Fluid Compatibility | Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options. | |||
Hazardous Environment Options | Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord or cord reel will be included. |
1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. Dimensions are approximations taken from base model and will vary according to options chosen.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 800 cSt for sizing requirements.
FC Filter Cart
V1P model shown,V1S model shown
Vacuum Dehydration Oil Purification System
A vacuum dehydrator is an industrial device that removes moisture and contaminants from lubricating oils and hydraulic fluids. It does so by utilizing vacuum pressure to lower the boiling point of water, allowing for efficient separation and extraction of impurities. For a vacuum dehydration oil purification system you can trust, turn to Bennett Filtration.
The V1 is our compact and mobile dehydration and high efficiency filtration solution. It prevents acidity and loss of lubrication properties caused by inefficient dehydration and high ingression. This vacuum oil dehydrator is ideal for rapidly removing all forms of water, including free, emulsified, and dissolved water and gas from hydraulic and lube oils.
Explore this product’s FSL specifications below. If you would like more information or a quote, contact us today. You can reach us by phone, email, or online form—we look forward to hearing from you and improving your hydraulic operations with top-quality equipment.
FSL SPECIFICATIONS
Model | V1P | V1S |
Height 1 | 50” (127 cm) | 50” (127 cm) |
Width 1 | 28” (71 cm) | 34” (86 cm) |
Depth 1 | 28” (71 cm) | 24” (61 cm) |
Weight 1 | 400 lbs (181 kg) | 400 lbs (181 kg) |
Inlet | ¾” male JIC | ¾” male JIC |
Outlet | ½” male JIC | ½” male JIC |
Operating Temperature | Fluid Temperature 32°F to 180°F (0°C to 82°C) | Ambient Temperature -4°F to 104°F (-20C to 40C) |
Materials of Construction | Frame Carbon steel or stainless steel | Filter assembly Aluminum and carbon steel |
Electric Motor | TEFC with overload protection | |
Electric Connection | 50’ (15 m) power cord supplied with machine. | |
Pump | Cast iron, positive displacement gear pump with internal relief. | |
Vacuum Pump | Dry Rotary Vane | |
Media Description | M Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000 | W Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2) |
Fluid Compatibility | Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester or skydrol fluid compatibility select fluid compatibility from special options. |
1. Dimensions are approximations taken from base model and will vary according to options chosen.
FC Filter Cart
Hydraulic Filter Cart
An industrial filter cart is a mobile filtration system designed to purify and transfer fluids in industrial settings. Depending on the viscosity of the fluids you need to purify, your cart needs will change. For lower-viscosity fluids, a low-viscosity filter cart is best. Bennett Filtration provides this equipment.
Our hydraulic filter cart is a fully self-contained mobile solution for bulk oil handling, fluid transfer, and reservoir or gearbox conditioning. It is ideal for lower-viscosity hydraulic oil, lube oil, and diesel fuel.
Take a look at the cart’s FSL specifications below to gauge if it’s a good fit for your operations. Then, if you would like more information or a quote, contact us today. You can reach us by phone, email, or online form. We look forward to helping you staff your hydraulic operations with the best equipment.
FSL SPECIFICATIONS
Dimensional | Height 45” (114 cm) | Width 20” (50 cm) | Depth 23” (58 cm) | Weight 125 lbs (57 kg) |
Connections | Inlet FC05-FC5: 1” male JIC (37° flare) FC10: 1.25” male JIC (37° flare) | Outlet FC05-FC10 1” male JIC (37° flare) FC20: 1.25” male JIC (37° flare) | Hoses FC05-FC5: 1” x 10 ft (2.4 m) FC10:1.25” x 10 ft (2.4 m) suction 1” x 10 ft (2.4 m) discharge | |
Operating Temperature | Fluid Temperature 30°F to 225°F (0°C to 105°C) | Ambient Temperature -4°F to 104°F (-20C to 40C) | ||
ΔP Indicator Trigger | 22 psi (1.5 bar). Consult factory for other options. | |||
Filter Assembly Bypass | 25 psid (1.7 bard). Consult factory for other options. | |||
Materials of Construction | Frame Industrial coated steel | Filter Assembly Aluminum head & canister | Hoses Reinforced synthetic | Wands Stainless Steel |
Electric Motor | TEFC, 56-215 frame
0.5-3 hp, 1450-1750 RPM | |||
Electric Connection | Voltages 230 V ac and under, single phase: 35’ (11 m) retractable cord reel included. NEMA 5-15 plug installed on Power Option 12. Voltages over 230 V ac: 35’ (11 m) power cord included. | |||
Motor Starter | MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection. | |||
Pump | Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures. | |||
Pump Bypass | Full bypass at 150 psi (10 bar)2 | |||
Pneumatic Option Air Consumption | ~40 cfm @ 80 p~40 cfm @ 80 psi3
35’ (11 m) retractable air hose included when pneumatic option selected (replaces electric cord reel).si3 | |||
Operating Temperature | M Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000 | A Microglass high performance media combined with water removal scrim. βx[C] ≥ 4000 | W Stainless steel wire mesh media βx[C] ≥ 2 | |
Viscosity | 2-5000 cSt4 | |||
Fluid Compatibility | Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options. | |||
Hazardous Environment Options | Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord will be included. |
1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. 10 GPM pump is rated for intermittent duty only at pressures above 100 psi. Continual operation with dual clogged filters resulting in operating pressures over 100 psi will reduce pump life and/or cause premature pump failure.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 200 cSt for sizing requirements.
FC Filter Cart
Remove water and particulate to extend fuel injector life and increase combustion engine fuel efficiency. Ideal for large mining and construction fueling depots, diesel fueled turbines, backup generators, and smaller day tank dispensing or on-board fueling truck applications. With options for adding nonpowered units to existing fuel dispensing lines, there’s a perfect COD for all of your diesel applications.
FSL SPECIFICATIONS
1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. Female pipe port.
3. L38-CSV element combines coalesce and separator element functions into a single element. TEFLON® is a registered trademark of DuPont.
FC Filter Cart
FC Filter Cart
A dedicated contamination solution for bulk oil handling, fluid transfer and reservoir or gearbox conditioning.
Enhance cleanliness by adding the FPL to an existing hydraulic system and extend the life of in-line filters.
FSL SPECIFICATIONS
Dimensional | Height 22” (58 cm) | Lenght 42” (107 cm) | Depth 12” (31 cm) | Weight 138 lbs (63 kg) |
Connections | Inlet with 3-way valve 1” FNPT | Outlet 1” FNPT | ||
Operating Temperature | Fluid Temperature 30°F to 225°F (0°C to 105°C) | Ambient Temperature -4°F to 104°F (-20C to 40C) | ||
ΔP Indicator Trigger | Standard MF110 Assemblies 18 psi (1.2 bar) | Special Options D1 + S1 (S75/D) 22 psi (1.5 bar) | Special Option D2 (DFN) 32 psid (2.2 bard) | Special Option P1 (PFH) 73 psid (5 bard) |
ΔP Indicator Trigger | Standard MF110 Assemblies 25 psid (1.7 bard) | Special Options D1 + S1 (S75/D) 25 psid (1.7 bard) | Special Option D2 (DFN) 50 psid (3.4 bard) | Special Option P1 (PFH) 102 psid (7 bard) |
Materials of Construction | Frame Carbon steel with industrial coating | |||
Electric Motor | TEFC, 56-145 frame 0.5-1 hp, 1450-1750 RPM | |||
Motor Starter | MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection. | |||
Pump | Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures. | |||
Pump Bypass | Full bypass at 150 psi (10 bar)2 | |||
Pneumatic Option Air Consumption | ~40 cfm @ 80 psi3 | |||
Media Description | M Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000 (βx ≥ 200) | A Microglass high performance media combined with water removal scrim. βx[C] ≥ 4000 (βx ≥ 200) | W Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2) | |
Viscosity | 2-5000 cSt4 | |||
Fluid Compatibility | Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or | |||
Hazardous Environment Options | Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord will be included. |
1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. 10 GPM pump is rated for intermittent duty only at pressures above 100 psi. Continual operation with dual clogged filters resulting in operating pressures over 100 psi will reduce pump life and/or cause premature pump failure.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 800 cSt for sizing requirements.
FC Filter Cart
High-Viscosity Filter Cart
An industrial filter cart is a portable system designed to filter and transfer fluids, ensuring that contaminants are removed from lubricants and hydraulic fluids during maintenance or service operations. This piece of equipment is essential for streamlining a variety of industrial operations. However, quality matters when it comes to the type of cart you invest in.
If you’re in need of a high-viscosity filter cart, Bennett Filtration has the perfect solution for your operations. Our product is a self-contained solution for high viscosity bulk oil handling, fluid transfer, and reservoir or gearbox conditioning. This heavy-duty filter cart is ideal for higher viscosity lube oil and highly contaminated fuel and hydraulic oil.
If you would like more information or a quote, contact us today by phone, email, or online form. We look forward to hearing from you and making your hydraulic operations as efficient as possible.
FSL SPECIFICATIONS
Dimensional | Height 57” (144 cm) | Width 30” (77 cm) | Depth 30” (77 cm) | Weight 351 lbs (159 kg) |
Connections | Inlet with 3-way valve FCL05-FCL5: 1” male JIC (37° flare) FCL10: 1.25” male JIC (37° flare) | Outlet FCL05-FCL10: 1” male JIC (37° flare) FCL20-FCL30: 1.25” male JIC (37° flare) | Hoses FCL05-FCL5: 1” x 10 ft (2.4 m) FCL10: 1.25” x 10 ft (2.4 m) suction1” x 10 ft (2.4 m) discharge | |
Operating Temperature | Fluid Temperature 30°F to 225°F (0°C to 105°C) | Ambient Temperature -4°F to 104°F (-20C to 40C) | ||
Materials of Construction | Housing Carbon steel with industrial coating | Hoses Reinforced synthetic | Wands Stainless steel | |
Electric Motor | TEFC, 56-215 frame 0.5-3 hp, 1450-1750 RPM, see Appendix for amp ratings. | |||
Electric Connection | Voltages 230 V ac and under, single phase: 35’ (11 m) retractable cord reel included. NEMA 5-15 plug installed on Power Option 12. Voltages over 230 V ac: 35’ (11 m) loose cord included. | |||
Motor Starter | MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection. | |||
Pump | Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures. | |||
Pump Bypass | Full bypass at 150 psi (10 bar)2 | |||
Pneumatic Option Air Consumption | ~40 cfm @ 80 psi3 35’ (11 m) retractable air hose included when pneumatic option selected. Replaces 35’ (11m) electric cord reel. | |||
Media Description | M Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] = 1000 (βx = 200) | A Microglass high performance media combined with water removal scrim. βx[C] = 1000 (βx = 200) | W Stainless steel wire mesh media βx[C] = 2 (βx = 2) | VTM β0.9[C] = 1000 particulate, insoluble oxidation by-product and water removal media |
Viscosity | 2-5000 cSt4 | |||
Fluid Compatibility | Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options. | |||
Hazardous Environment Options | Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord or cord reel will be included. |
1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. 10 GPM pump is rated for intermittent duty only at pressures above 100 psi. Continual operation with dual clogged filters resulting in operating pressures over 100 psi will reduce pump life and/or cause premature pump failure.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 800 cSt for sizing requirements.
FC Filter Cart
CFUM9 Model shown (2x MF90 in series)
Compact Filter Unit
A filter unit in a hydraulic system is what removes contaminants and impurities from the hydraulic fluid, ensuring clean circulation that protects system components and maintains optimal efficiency. The unit consists of a filter element inside housing that allows fluid to flow through. Additional components may include a bypass valve to prevent pressure buildup and access ports for monitoring and maintenance purposes. Though it may seem that a large piece of equipment is necessary to house all these components, that’s not necessarily true.
Bigger isn’t always better. The Compact Filter Unit from Bennett Filtration provides you with the best filtration at a size you can take anywhere. Tried and true, the CFU is the ultimate filtration system in power and mobility. And with easy-to-change cartridge-style MF90s, you can rest easy knowing your filtration will always exceed your expectations.
If you would like more information or a quote for an industrial filtration unit that won’t take up too much space, contact us today. You can reach us by phone, email, or online form. We look forward to helping you see what a Compact Filter Unit can do for your operations.
FSL SPECIFICATIONS
Dimensional | Height 21” (54 cm) | Lenght 21” (54 cm) | Width 12” (31 cm) | Weight 47 lbs (21 kg) | |
Connections | Inlet ¾” male JIC with 37° flare | Outlet ½” male JIC with 37° flare | Hoses ¾” x 8 ft (2.4 m) suction female JIC or BSPP swivel ½” x 8 ft (2.4 m) discharge female JIC or BSPP swivel | ||
Operating Temperature | Fluid Temperature 30°F to 225°F ½” x 8 ft (2.4 m) discharge female JIC or BSPP swivel | Ambient Temperature 4°F to 104°F ½” x 8 ft (2.4 m) discharge female JIC or BSPP swivel | |||
ΔP Indicator Trigger | 22 psi (1.5 bar). Consult factory for other options. | ||||
Filter Assembly Bypass | 25 psid (1.7 bard). Consult factory for other options. | ||||
Materials of Construction | Frame Powder coated aluminum | Filter Assembly Aluminum head | Hoses Reinforced synthetic | Wands Stainless steel | Element Bypass Valve Nylon |
Electric Motor | TEFC, 56C frame 7/16 hp, 1450-1750 RPM | ||||
Electric Connection | 15’ (4.6 m) cord included installed on machine. | ||||
Pump | Positive displacement gear pump with relief valve. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures. | ||||
Pump Bypass | Full bypass at 150 psi (10 bar)2 | ||||
Pneumatic Option Air Consumption | ~15 cfm @ 60 psi3 | ||||
Media Description | M High performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000 (βx ≥ 200) | A High performance media combined with water removal scrim. βx[C] 4000 (βx ≥ 200) | W Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2) | ||
Viscosity | Max viscosity rated for 200 cSt.4 | ||||
Fluid Compatibility | Petroleum and mineral based fluids (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options. | ||||
Hazardous Environment Options | Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D.Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord will be included. |
1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. Selecting pneumatic power option removes electric cord.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 200 cSt for sizing requirement.
FC Filter Cart
A fully self-contained mobile solution for bulk oil handling, fluid transfer and reservoir or gearbox conditioning.
Ideal for lower viscosity hydraulic oil, lube oil and diesel fuel.